Regulations of Connecticut State Agencies (Last Updated: June 14,2023) |
Title19a Public Health and Well-being |
SubTitle19a-333-1_19a-333-13. Asbestos-Containing Materials in Schools |
Sec.19a-333-3. Inspection and reinspections
-
(a) Inspection
(1) All local education agencies are required to inspect each school building that they lease, own or otherwise use as a school building to identify all locations of friable and nonfriable ACBM except for those buildings which have been inspected as required by the Act and for which documentation of said inspection was filed with the State as required by the Act. The inspection shall be conducted as described under subdivisions (2) and (3) of this subsection prior to use as a school building.
(2) Each inspection shall be made by an accredited inspector.
(3) For each area of a school building, except as excluded under section 19a-333-13 of the regulations of Connecticut State Agencies, each person performing an inspection shall:
(A) visually inspect the area to identify the locations of all suspected ACBM;
(B) touch all suspected ACBM to determine whether it is friable;
(C) identify all homogeneous areas of friable suspected ACBM and all homogeneous areas of nonfriable suspected ACBM;
(D) for each identified homogeneous area that is not assumed to be ACM, collect and submit for analysis bulk samples under sections 19a-333-4 and 19a-333-5 of the regulations of Connecticut State Agencies;
(E) assess, under section 19a-333-6 of the regulations of Connecticut State Agencies, friable material in areas where samples are collected, friable material in areas that are assumed to be ACBM, and friable ACBM identified during a previous inspection;
(F) record the following and submit to the person designated under section 19a-333-2 of the regulations of Connecticut State Agencies, a copy of such record for inclusion in the management plan within thirty (30) days of the inspection:
(i) an inspection report with the date of the inspection signed by each accredited person making the inspection, state of accreditation, and if applicable his or her accreditation number;
(ii) an inventory of the locations of the homogeneous areas where samples are collected, exact location where each bulk sample is collected, dates that samples are collected, homogeneous areas where friable suspected ACBM is assumed to be ACM, and homogeneous areas where nonfriable suspected ACBM is assumed to be ACM;
(iii) a description of the manner used to determine sampling locations, the name and signature of each accredited inspector who collected the samples, state of accreditation, and, if applicable, his or her accreditation number;
(iv) a list of whether the homogeneous areas identified under this subparagraph are surfacing material, thermal system insulation, or miscellaneous material;
(v) assessments made of friable material, the name and signature of each accredited inspector making the assessment, state of accreditation, and if applicable, his or her accreditation number.
(b) Reinspection
(1) At least once every three (3) years after a management plan is implemented, each local education agency shall conduct a reinspection of all friable and nonfriable known or assumed ACBM and any not previously identified suspect ACBM, regardless of whether or not these areas were included in the original inspection and management plan, in each school building that they lease, own, or otherwise use as a school building. Each local education agency shall submit to the Department within thirty (30) days of the reinspection, documentation that a reinspection has been performed. This documentation shall be submitted on a form prescribed by the Commissioner.
(2) Each inspection shall be made by an accredited inspector.
(3) For each area of a school building, each person performing a reinspection shall:
(A) visually reinspect, and reassess, under section 19a-333-6 of the regulations of Connecticut State Agencies, the condition of all friable known or assumed ACBM;
(B) visually inspect material that was previously considered nonfriable ACBM and touch the material to determine whether it has become friable since the last inspection or reinspection;
(C) visually inspect and assess under section 19a-333-6 of the regulations of Connecticut State Agencies, materials such as, but not restricted to, ceiling tile, wallboard, plaster walls, linoleum, fire doors, duct insulation and vibration dampening cloth, which are considered suspect ACBM;
(D) identify any homogeneous areas with material that has become friable since the last inspection or reinspection;
(E) for each homogeneous area of newly friable material that is already assumed to be ACBM, collect and submit bulk samples for analysis in accordance with sections 19a-333-4 and 19a-333-5 of the regulations of Connecticut State Agencies;
(F) assess, under section 19a-333-6 of the regulations of Connecticut State Agencies, the condition of the newly friable material in areas where samples are collected, and newly friable materials in areas that are assumed to be ACBM;
(G) reassess, under section 19a-333-6 of the regulations of Connecticut State Agencies, the condition of friable known or assumed ACBM previously identified;
(H) record the following and submit to the person designated under section 19a-333-2 of the regulations of Connecticut State Agencies a copy of such record for inclusion in the management plan within thirty (30) days of the reinspection:
(i) the date of the reinspection, the name and signature of the person making the reinspection, state of accreditation, and if applicable, his or her accreditation number, and any changes in the condition of known or assumed ACBM;
(ii) the exact locations where samples are collected during the reinspection, a description of the manner used to determine sampling locations, the name and signature of each accredited inspector who collected the samples, state of accreditation, and, if applicable, his or her accreditation number;
(iii) any assessments or reassessments made of friable material, the name and signature of the accredited inspector making the assessments, state of accreditation, and if applicable, his or her accreditation number.
(c) General. Thermal system insulation that has retained its structural integrity and that has an undamaged protective jacket or wrap that prevents fiber release shall be treated as nonfriable and therefore is subject only to periodic surveillance and preventive measures as necessary.
(Effective December 1, 1992)